| HS Code | 617195 |
| Product Name | FIRST EBISU S-Series Lower Acid EVA Film S406 |
| Series | S-Series |
| Model | S406 |
| Type | Lower Acid EVA Film |
| Base Resin | EVA |
| Thickness | 0.40 mm |
| Width | 1000 mm |
| Length | 200 m |
| Density | 0.94 g/cm³ |
| Melting Point | 70-90°C |
| Light Transmittance | ≥91% |
| Gel Content | ≥75% |
| Adhesion To Glass | ≥50 N/cm |
| Adhesion To Backsheet | ≥40 N/cm |
| Volume Resistivity | ≥1×10^15 Ω·cm |
| Dielectric Breakdown Voltage | ≥15 kV/mm |
| Tensile Strength | ≥10 MPa |
| Elongation At Break | ≥400% |
| Shrinkage | ≤3% |
| Water Absorption | ≤0.1% |
| Uv Cut Off Wavelength | ≤360 nm |
| Acid Value | ≤0.1 mg KOH/g |
| Curing Temperature | 145-150°C |
| Curing Time | 10-20 min |
| Storage Temperature | ≤30°C |
| Shelf Life | 6 months |
As an accredited FIRST EBISU S-Series Lower Acid EVA Film S406 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
FIRST EBISU S-Series Lower Acid EVA Film S406 is specified in heterojunction and tunnel-oxide passivated contact module layups where residual vinyl acetate hydrolysis would otherwise attack the indium tin oxide buffer layer and low-temperature silver paste. The formulation addition ratio in the layup is 0.45 mm per sheet, or 0.45–0.50 mm front with 0.60 mm rear for glass-glass bifacial stacks with textured rear glass; this corresponds to a film mass addition of 0.43–0.58 kg/m² per layer and an interlayer mass fraction of 5.2–6.4% w/w of the unlaminated glass-cell-glass mass. No peroxide, silane coupling agent, or plasticizer is added at the layup station; the film is used as supplied, and any blend with offcut material is rejected above 2% w/w of total layup mass. The qualification path is IEC 61215-1:2021 Test MQT 13 damp heat 1,000 h at 85 °C / 85% RH, with safe construction verified under IEC 61730-1:2023 and wet leakage current under IEC 61730-2:2023; acetate emission is compared by ion chromatography after thermal desorption against the S-Series lot-specific upper limit rather than against generic EVA reference data. The film is used within the REACH registration for ethylene-vinyl acetate copolymer; RoHS Directive 2011/65/EU Annex II restrictions for lead, cadmium, mercury, hexavalent chromium, PBB, and PBDE are verified by the film supplier’s documentation, not altered by downstream lamination. The acetate-related failure signature in heterojunction modules is a rise in series resistance exceeding 5% after damp heat, measured by electroluminescence and current-voltage flash testing, so acceptance is tied to electrical performance retention rather than visual appearance only.
On a 3-chamber flatbed laminator with platen dimensions 2.1 m × 4.3 m, the chamber is evacuated to ≤3 mbar for 360–420 s at 140–145 °C, then membrane pressure of 800–1,000 mbar is applied for 600–720 s at 145–150 °C; the cured interlayer gel content is checked by solvent extraction per ASTM D2765-16 and maintained at 75–90%, while edge bleed is constrained to 2–4 mm per side to avoid conductive path formation at cell edges. Crosslinking uniformity across a 2.0 m module width is verified by surface pyrometer mapping; a temperature spread larger than ±3 °C across the platen is known to produce gel content gradients above 5% between center and edge, which in turn alters three-point bending stiffness and damp-heat adhesion. Lot-to-lot variations are screened at incoming inspection by Fourier-transform infrared spectroscopy and melt flow rate per ISO 1133-1:2022 at 190 °C / 2.16 kg; the actual limits are lot-specific and must be taken from the manufacturer certificate. In salt-mist service, modules with S406 are qualified under IEC 61701:2020 severity level 1 or 2 and ammonia resistance under IEC 62716:2013; these tests expose the module to saline mist or ammonia vapor for 1,000 h, after which insulation resistance must remain above 40 MΩ·m² per IEC 61215-1:2021 sequence. The terminal product range covers glass-backsheet monofacial modules and glass-glass bifacial modules in the 400–700 W class, particularly downstream utility specifications where salt-mist and ammonia resistance are mandatory.
Unitized curtain wall elements installed in high-humidity coastal districts are subject to repeated condensation at the glass edge and thermal cycling from -20 °C to 70 °C on the unshaded spandrel surface; if the encapsulant releases free acetate under those conditions, the acetate migrates to the cell edge and accelerates corrosion of the busbar and conductive adhesive. S406 is laminated between two 3.2 mm heat-strengthened or tempered glass lites at 0.6 mm in a 3.2 mm / 0.6 mm / 3.2 mm stack; the S406 mass fraction is 6.0–6.5 wt% of the finished laminate, and the formulation addition ratio is 1.0–1.2 kg/m² when the film is used both behind and in front of a semi-transparent cell matrix. The glazing is qualified under IEC 61215-1:2021 and IEC 61730-1:2023, with impact safety per EN 12600:2002 class 1B1 and lamination durability under EN ISO 12543-4:2021; the edge seal is based on ASTM C1549-16 conditions for butyl compatibility to avoid plasticizer migration from sealant into the EVA layer.
Manufacturing lines that run glass-glass BIPV with S406 commonly combine a nip-roll pre-laminator at 80–110 °C and an autoclave at 12–14 bar and 135–140 °C for 90–180 min; the lower lamination temperature compared with PVB autoclaving reduces temper warpage on thin 2.8 mm heat-strengthened glass. The critical process boundary is that total cycle time above 120 °C must remain below 45 min in the flatbed line when a low-E coating is present, because extended heat causes silver enamel frit to migrate into the EVA melt and increases yellowness index to above 1.5 measured by ASTM D1003. For structural curtain wall attachment, the laminate is not considered a structural interlayer under EN 16612:2019; point-fixing hardware must engage through-hole metal bushings, and the S406 edge must be isolated from acetoxy-cure silicone weatherseal by a polyisobutylene primary seal to preserve the low-acid interface at the laminate perimeter. Terminal products include vision-glass BIPV spandrels, balcony glazing with integrated PV, and skylight units where the electrical output of the semi-transparent cell matrix is 80–160 W/m² depending on cell spacing.
Table 1. Compliance verification matrix.
| Verification point | Standard method / clause | Acceptance or test parameter |
| Heterojunction / TOPCon modules | IEC 61215-1:2021 MQT 13; IEC 61730-1:2023; IEC 62788-1-4 | Film lot acetate below supplier cap; gel content 75–90% per ASTM D2765-16 |
| BIPV curtain wall | EN 12600:2002 1B1; EN ISO 12543-4:2021; IEC 61215-1:2021 | Yellowness index ≤1.5 per ASTM D1003; edge bleed ≤3 mm |
| Decorative mesh / LED laminate | EN 12600:2002 1B1; UL 94 V-0; ASTM D1003 | Haze ≤1.5%; peel adhesion ≥40 N/15 mm after damp heat 500 h |
| Photovoltaic sunroof | IEC 61215-1:2021; ECE R43 Rev.4 | Total S406 thickness ≥0.76 mm; fill factor drop ≤3% after 1,000 h damp heat |
| Polycarbonate security glazing | EN 356:2000 P4A; ASTM E1996-23; ASTM E1886-22 | Post-UV haze ≤1.0% per ISO 4892-2:2013; warp ≤2.0 mm/m |
| Greenhouse agrivoltaic panel | IEC 61215-1:2021; EN 12600:2002 1B1; IEC 61701:2020 | Edge bleed ≤2 mm; PAR transmission above 65% in crop-active spectrum |
Copper mesh, silver ceramic frit, brass wire cloth, and LED conductive traces embedded between tempered glass lites are degraded by acetic acid through electrochemical migration when the interlayer retains free acetate under high-humidity indoor service. S406 is placed over the conductive layer as a 0.38–0.45 mm film, giving a formulation addition ratio of 0.36–0.43 kg/m² and 3.5–4.5 wt% of the finished decorative laminate; if the conductive layer is buried between two S406 sheets, the total film addition is 0.76–0.90 mm and 6.8–8.2 wt%. The compliance matrix includes EN 12600:2002 class 1B1 for impact, UL 94 V-0 for flammability of the laminate edge including any PET carrier film, and ASTM D1003 haze ≤1.5% after lamination; for LED-embedded assemblies, adhesion loss is assessed by 90° peel after damp heat 500 h, with acceptance set at ≥40 N/15 mm and no cohesive glass failure. The lower-acid composition is specified only for interior decorative safety glass where the service temperature does not exceed 60 °C; exterior use requires edge sealing because moisture uptake above 0.1% w/w in the cured film will raise haze after thermal cycling.
Vacuum-bag lamination is performed at 125–135 °C under 0.6–0.8 bar vacuum for 45–60 min, with cooling to ≤40 °C before bag release to prevent print-through of the conductive mesh into the EVA surface. The vacuum bag method is preferred over flatbed membrane lamination for embedded LED circuits because the direct pressure of a diaphragm above 0.9 bar can crush 0.2 mm height solder joints and cause optical short circuits. Batch-to-batch variation in copper mesh oxidation is controlled by pre-laminating the upper S406 sheet to glass at 110 °C for 120 s before the conductive layer is placed, a process step that reduces microbubble defects at the mesh crossover points. Terminal products include decorative stair partitions, illuminated wall cladding, embedded-LED display glass, and touch-sensor panel laminates for retail interiors.
The replacement of a plasticized PVB interlayer with S406 in a photovoltaic sunroof stack removes the need for autoclave pressure while maintaining the electrical isolation required between the embedded cell string and the automotive ground plane. The layup is 2.1 mm tinted chemically strengthened glass / 0.38 mm S406 / cell matrix / 0.38 mm S406 / 2.1 mm clear glass; the total S406 mass fraction is 5.0–5.8 wt% of the finished laminate and the formulation addition ratio is 0.72–0.76 kg/m². The finished pane is validated under IEC 61215-1:2021 for photovoltaic performance and ECE R43 Rev.4 for non-windshield glazing; where the pane is installed as a roof glazing unit, the fabricator must also verify retention after headform impact because EVA interlayers below 0.76 mm total thickness do not show the same strain-hardening as PVB under high-speed loading.
Flatbed vacuum lamination is conducted at 135–145 °C with a vacuum hold of 300–360 s at ≤3 mbar and a membrane press stage of 700–900 mbar for 480–600 s; the lower temperature avoids thermally induced bow in chemically strengthened glass above 150 °C and reduces the residual peroxide monomer that would otherwise fog the interior surface during summer roof temperatures of 90 °C. The low-acid characteristic is most visible in automotive roof service because the closed cabin temperature drives free acetate migration to the silver busbar and the moisture barrier layer; failure manifests as a drop in fill factor of ≥3% after 1,000 h damp heat. Terminal products include solar sunroof laminates, photovoltaic roof panels for electric vehicles, and semi-transparent roof glazing where the embedded cell spacing yields 60–140 W/m² and the glass stack remains below 5.0 kg/m².
In forced-entry-resistant glazing, co-lamination of polycarbonate and heat-strengthened glass through S406 is performed below the glass transition temperature of the polycarbonate sheet to prevent dimensional collapse; the film therefore functions as the adhesive layer rather than as a structural core. The layup uses a 4.0–6.0 mm polycarbonate sheet, a 0.76 mm S406 film, and a 3.0–4.0 mm heat-strengthened glass lite, giving a formulation addition ratio of 0.73 kg/m² and an interlayer mass fraction of 4.0–5.0 wt% of the total lamination. The security classification is verified under EN 356:2000 class P4A for burglar resistance, and windborne debris testing under ASTM E1996-23 and ASTM E1886-22 is used for hurricane-prone installations; the EVA layer is not credited as the primary blast or impact layer but is intended to retain glass shards and bond the polycarbonate core to the glass exterior.
The lamination process uses a vacuum bag at 115–125 °C for 60–90 min with a controlled cooling ramp of 0.5–1.0 °C/min from 110 °C to 40 °C; rapid cooling above 1.5 °C/min produces differential contraction between the polycarbonate and glass, causing warp readings above 2.0 mm/m and increasing edge delamination. Because polycarbonate absorbs water and releases gas at elevated temperature, the sheet must be pre-dried at 80 °C to ≤0.02% w/w moisture before lamination; otherwise, bubbles form at the S406–polycarbonate interface and cannot be removed after cure. The low-acid S406 is specified instead of higher-acid EVA because the polycarbonate surface is susceptible to stress cracking from acetic acid at the interface; this avoids a haze increase above 1.0% after 1,000 h UV exposure per ISO 4892-2:2013 cycles. Published data for this specific asymmetric EVA-polycarbonate laminate configuration is limited; each security glazing design must undergo full-scale forced-entry testing rather than relying on coupon-level adhesion values. Terminal products include security windows for embassies, hurricane-glazed storefronts, and glazed ballistic panels where a polycarbonate core is used with glass-clad exterior surfaces.
Table 2. Lamination equipment parameter matrix.
| Process zone | Equipment | Thermal schedule | Pressure / vacuum | Control limit |
| Heterojunction / TOPCon flatbed | 3-chamber flatbed 2.1 m × 4.3 m | 140–150 °C | ≤3 mbar, press 800–1,000 mbar | Gel content 75–90%; edge bleed 2–4 mm |
| BIPV autoclave | Nip-roll pre-laminator + autoclave | 80–110 °C pre-lamination, 135–140 °C | 12–14 bar | Time above 120 °C ≤45 min |
| Decorative mesh vacuum bag | Vacuum bag | 125–135 °C | 0.6–0.8 bar vacuum | Cool to ≤40 °C before release |
| Solar sunroof flatbed | Flatbed | 135–145 °C | ≤3 mbar, press 700–900 mbar | Press 480–600 s |
| Polycarbonate security vacuum bag | Vacuum bag | 115–125 °C | Cooling ramp 0.5–1.0 °C/min | Warp ≤2.0 mm/m |
| Greenhouse glass-glass flatbed | Flatbed | 145–150 °C | ≤3 mbar, press 800–1,000 mbar | Edge bleed ≤2 mm |
Greenhouse roof panels carrying monofacial PERC cell strips at 30–50% coverage require an encapsulant that does not release free acetate into the condensation layer at the glass edge, because the aluminum framing and junction-box contacts in agricultural tunnels are exposed to nightly humidity cycles. S406 is used as the front interlayer at 0.45 mm and as the rear interlayer at 0.45 mm in a 3.2 mm / 3.2 mm glass-glass laminate, yielding a formulation addition ratio of 0.86–0.90 kg/m² and a mass fraction of 5.0–5.5 wt%; no extra crosslinker is added in the greenhouse panel layup. The panel is qualified under IEC 61215-1:2021 for thermal cycling TC 200 and damp heat MQT 13, with UV preconditioning per ISO 4892-2:2013 and salt-mist corrosion resistance under IEC 61701:2020; mechanical safety for overhead glazing is evaluated by EN 12600:2002 class 1B1.
Flatbed lamination uses a 2.0 m × 3.0 m platen at 145–150 °C with vacuum hold 300–360 s and press 600–720 s at 800–1,000 mbar; because greenhouse panels are mounted at low slope, edge bleed is limited to ≤2 mm to reduce the path for ethylene-vinyl acetate degradation products to reach the aluminum glazing bar. The lower-acid S406 reduces the risk that condensation runoff from the glass edge reaches an acidic pH below 4.5, which is known to accelerate pitting of the aluminum frame and degradation of the junction-box cable gland. Terminal products include semi-transparent agrivoltaic roof panels, greenhouse façade modules, and integrated PV strips for horticultural light-modulation glazing where the panel maintains PAR transmission above 65% in the crop-active spectrum.
Competitive FIRST EBISU S-Series Lower Acid EVA Film S406 prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The FIRST EBISU S-Series Lower Acid EVA Film S406 is an ethylene-vinyl acetate encapsulant film intended for photovoltaic module lamination. It is identified as a lower-acid grade within the S-Series, which indicates a formulated resin and additive system designed to reduce free carboxylic acid generation relative to conventional EVA encapsulants under damp heat exposure. The film is positioned for front-side or back-side encapsulation of crystalline-silicon cells in glass-backsheet or glass-glass constructions. Unlike standard EVA films that rely primarily on vinyl acetate content and peroxide curing, S406 is formulated with acid-scavenging and hydrolysis-control chemistry to limit acetic acid accumulation in the module package. The product is supplied as a roll good that is vacuum packaged for moisture exclusion and should be conditioned to room temperature before lamination. Nominal film thickness is typically selected from 0.40 mm to 0.60 mm depending on cell topography and backside coverage; the exact roll width, thickness, and lot-specific values for S406 should be confirmed against the manufacturer’s current datasheet.
During 85 °C/85% RH damp heat exposure, acetic acid generation in ethylene-vinyl acetate encapsulants proceeds primarily through hydrolytic deacetylation of vinyl acetate units when water permeates the laminate. In standard EVA grades, the vinyl acetate content is commonly between 28 wt% and 33 wt%, and the hydrolysis reaction releases acetic acid at the glass-cell interface. The S406 lower-acid grade is formulated to reduce the free acetate reservoir without necessarily moving the vinyl acetate content outside the range required for adhesion and cure. The acid reduction mechanism may include inorganic acid acceptors, sacrificial hydrolysis agents, or modified cure packages that lower residual peroxide decomposition byproducts. The observable result is a lower titratable acid number after damp heat aging when measured by ion chromatography or titration on laminate extracts. Published data for this specific S406 formulation is limited; class-level data for lower-acid EVA encapsulants indicate a reduction in acetic acid generation of approximately 30% to 70% compared with standard high-acid EVA, depending on the additive system. This reduction is not zero-acid performance and should not be interpreted as elimination of carboxylic acid species in the encapsulant.
Under 85 °C/85% RH damp heat, free acetic acid accumulates at the glass-EVA interface and can attack the front glass and cell metallization. The primary degradation pathway is potential-induced degradation shunting of p-type crystalline-silicon cells under negative bias, as described in IEC TS 62804-1. The S406 lower-acid film is designed to reduce the concentration of mobile acetate ions that contribute to surface polarization and electrochemical corrosion. Volume resistivity of a properly crosslinked lower-acid EVA encapsulant is typically in the range of 1.0 × 10^14 Ω·cm to 1.0 × 10^15 Ω·cm at 23 °C when measured according to IEC 60093. The value is not solely determined by acid content; crosslinking density, residual peroxide, and absorbed moisture also affect ionic mobility. In comparison with standard EVA, the lower-acid grade shifts the failure mode from rapid acetate-driven shunting toward slower moisture-driven degradation; it does not replace the need for edge sealing or an appropriate backsheet moisture barrier in high-humidity installations. Polyolefin encapsulants generally show still lower free-acid content, but S406 retains the adhesion and established lamination behavior associated with EVA.
Transmittance of a laminated EVA encapsulant is measured on glass/EVA/glass coupons using ASTM D1003-21. For clear lower-acid EVA films in the S-Series, the optical function is comparable to standard EVA only if the acid-scavenging additives do not increase haze. Published class data for clear EVA encapsulants indicate total luminous transmittance values above 90% and haze values below 5% after complete lamination. The S406 model is typically used as a clear or ultra-clear film; pigmented or white variants are separate formulations. Gel fraction after lamination is determined by solvent extraction according to ASTM D2765-16. Complete cure is generally defined as an insoluble gel fraction of 75% to 90%; partial cure below 70% can leave residual free vinyl acetate and peroxide decomposition products that raise the mobile acid pool. The lower-acid claim is therefore meaningful only after the module has passed the full crosslinking window in the laminator. If the film is undercured because of a short dwell time or a temperature drop at the edge of the laminate, acetic acid generation may remain high even with the acid-scavenger package.
| Test standard | Property measured | Relevance to S406 |
|---|---|---|
| ASTM D2765-16 | Insoluble gel fraction by solvent extraction | Confirms crosslink density after lamination |
| ASTM D1003-21 | Luminous transmittance and haze | Verifies optical clarity through glass/EVA/glass |
| IEC 60093 | Volume resistivity | Indicates leakage current potential under bias |
| IEC TS 62804-1 | Potential-induced degradation resistance | Assesses lower-acid contribution to PID stability |
| IEC 61215-2:2021 | Damp heat and module qualification | Provides aging environment for acid generation tests |
Although the lower-acid additive package is designed to be drop-in on most production lines, the S406 film can require a modified vacuum lamination profile if the acid scavenger affects the peroxide cure kinetics. Typical flat-plate laminators for crystalline-silicon modules operate at platen temperatures between 145 °C and 165 °C, with vacuum levels below 3 mbar during draw-down and hydraulic pressure of 0.6 bar to 1.0 bar above atmospheric during the press stage. Total cycle time is commonly 10 min to 18 min depending on chamber design and glass thickness. The lamination process has three pressure stages: vacuum draw-down to remove trapped air, a press step to wet the cells and ribbons, and a cure step at constant pressure to reach the target gel fraction. For lower-acid EVA grades, the peroxide decomposition rate may be slightly retarded if the acid acceptor disrupts the radical curing reaction, requiring an additional 30 s to 90 s of dwell at the upper platen temperature. Conversely, if the acid-scavenger filler increases thermal conductivity, the film may reach cure temperature earlier and allow a 5% to 10% reduction in total cycle time after line validation. These adjustments should be confirmed by gel-fraction sampling at the center and edge of the laminate; a difference greater than 10% between center and edge indicates nonuniform heat transfer. Material specifications for S406 include an uncured melt flow rate typical of EVA encapsulant films, usually 20 g/10 min to 40 g/10 min at 190 °C/2.16 kg according to ISO 1133-1:2022. Density is generally in the range of 0.94 g/cm³ to 0.97 g/cm³ according to ASTM D792-20.
Adhesion data for lower-acid EVA laminates are typically generated on a two-chamber laminator using glass/EVA/backsheet coupons and a 180° peel test at a crosshead speed of 50 mm/min. The S406 film must retain adequate adhesion to glass with or without a silane coupling agent, because the acid-scavenger chemistry can alter the silanol condensation equilibrium at the glass surface. In class-level EVA formulations, peel adhesion to glass above 40 N/cm is generally considered acceptable for module reliability, although the exact acceptance limit depends on cell size and backsheet type. Lower acid does not automatically imply lower adhesion; premature loss of adhesion is usually caused by moisture at the glass interface, not by the acid-reduction package. The largest difference from standard EVA is therefore seen after damp heat, where S406 is intended to preserve interfacial adhesion longer by reducing the plasticizing and hydrolytic effects of free acetic acid.
In a dry laminate at 23 °C, volume resistivity and wet leakage current are controlled by the concentration of mobile ionic species in the encapsulant and the absorbed moisture content. The target volume resistivity for EVA encapsulants is generally above 1.0 × 10^14 Ω·cm; after 1,000 h of damp heat, the value may fall by one to two orders of magnitude as water enters the film. The S406 lower-acid grade is intended to limit the additional conductivity increase caused by acetic acid dissociation. Wet leakage current testing according to IEC 61215-2:2021 measures the insulation resistance of the module with the laminate immersed or wetted; high free-acid content can produce localized conductive paths along cell edges and ribbon exits. In comparison with standard EVA, S406 reduces the available weak electrolyte reservoir. In comparison with a peroxide-free polyolefin encapsulant, S406 has a higher base ionic content but maintains lower overall processing cost and established lamination behavior. End users should not use lower-acid EVA as a substitute for a damp heat-rated backsheet or for proper edge sealing.
Before lamination, the dominant handling risks are premature moisture uptake and loss of free peroxide. S406 should be stored in sealed aluminum-foil bags at 5 °C to 30 °C and allowed to reach room temperature before opening to prevent condensation on the film surface. Once opened, the film should be used within 24 h to 48 h in high-humidity environments or re-vacuum-packed with desiccant. The product is incompatible with amine-based curing agents, which can neutralize the acid-scavenger system and cause premature crosslinking or discoloration. Lamination should not be performed below a dew point of 10 °C on cold glass surfaces, because surface moisture can hydrolyze vinyl acetate groups before the cure stage. The lower-acid claim is a formulation-specific characteristic, not a guarantee of zero acetic acid emission; module qualification under the intended climate remains necessary.