| HS Code | 988650 |
| Product Name | KENGO ST EVA Film |
| Material | Ethylene Vinyl Acetate |
| Application | Photovoltaic module encapsulation |
| Appearance | Transparent film |
| Thickness | 0.5 mm |
| Width | 1000 mm |
| Length | 200 m |
| Density | 0.93 g/cm³ |
| Va Content | 28-33% |
| Melt Flow Index | 25 g/10 min |
| Light Transmittance | ≥91% |
| Haze | ≤2% |
| Crosslinking Degree | ≥75% |
| Adhesion To Glass | ≥70 N/cm |
| Adhesion To Backsheet | ≥50 N/cm |
| Tensile Strength | ≥18 MPa |
| Elongation At Break | ≥600% |
| Shrinkage | ≤3% |
| Volume Resistivity | ≥1×10^15 Ω·cm |
| Dielectric Strength | ≥20 kV/mm |
| Melting Point | 65-75°C |
| Operating Temperature | -40°C to +85°C |
| Shelf Life | 12 months |
| Storage Conditions | 5-30°C, dry, away from direct sunlight |
| Certifications | TUV, IEC, UL |
As an accredited KENGO ST EVA Film factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | |
| Shipping | |
| Storage |
In monocrystalline and polycrystalline silicon module manufacturing, KENGO ST EVA Film is processed as the front-side encapsulant placed between glass and cell string and as the rear-side encapsulant between cell string and backsheet or second glass layer. The film is qualified against IEC 61215-2:2021 for module design approval, IEC 61730-2:2023 for safety requirements, and UL 1703 for North American listings; incoming melt mass-flow rate is tested per ISO 1133-1:2022 at 190 °C/2.16 kg within 20–45 g/10 min to ensure consistent cell embedding before crosslinking. Formulation addition ratios for this encapsulant class are 100 phr ethylene-vinyl acetate base resin, 0.75–1.5 phr peroxide initiator, 0.2–0.5 phr of 3-methacryloxypropyltrimethoxysilane coupling agent, 0.1–0.35 phr phenolic-phosphite antioxidant package, and 0.15–0.35 phr UV absorber when the film is used in front-side exposure. Lamination is executed on vacuum laminators with oil-heated platens of 3.2 m × 2.2 m usable area; the typical cycle is 5 min evacuation at -0.095 MPa followed by 10–13 min pressing at 0.09–0.12 MPa and 145–150 °C. Gel content after lamination is measured by ASTM D2765-16 and is held between 75% and 90%; production batches falling below 70% show cell displacement after thermal cycling per IEC 61215-2:2021 MQT 11, while gel content above 92% increases compressive stress at cell interconnects and can produce micro-cracks after mechanical load testing. Optical transmittance after lamination is evaluated per ASTM D1003-21 in the 400–1100 nm range and should remain at or above 91%; damp heat aging at 85 °C/85% RH for 1000 h should not increase haze by more than 5%. Peel strength to glass is tested by ASTM D903-98 with 180° peel geometry, targeting at least 40 N/15 mm after damp heat exposure. The terminal finished product is a framed or frameless photovoltaic module rated between 400 W and 700 W; published data for this specific configuration is limited, and module-level qualification is required before field deployment.
| Test method | Property | Condition | Typical acceptance range |
|---|---|---|---|
| ISO 1133-1:2022 | Melt mass-flow rate | 190 °C, 2.16 kg | 20–45 g/10 min |
| ASTM D1003-21 | Luminous transmittance | 400–1100 nm | ≥91% |
| ASTM D2765-16 | Gel content | Xylene extraction, 150 °C/15 min | 75–90% |
| ASTM D903-98 | Peel strength to glass | 180° peel, 25 °C | ≥40 N/15 mm |
KENGO ST EVA Film is converted into laminated side glazing, roof panels, and rear quarter windows where a non-PVB interlayer is adopted for improved sound damping or simplified cold bending. The film is supplied in 0.38 mm, 0.76 mm, or 1.52 mm thickness and is compounded with 0.2–0.5 wt% silane adhesion promoter; UV absorber content is 0.2–0.4 phr for edge-frit shading applications. Pre-lamination is performed in a vacuum-bag system at 110–120 °C for 8–12 min under -0.08 MPa, followed by autoclave curing at 135–145 °C and 1.1–1.4 MPa for 60–90 min. The most common production bottleneck occurs at the black enamel frit step, where frit height above 0.3 mm prevents complete EVA fill and generates edge bubbles when de-airing pressure is insufficient below -0.07 MPa. Adhesion is assessed by compressive shear per ISO 12543-4:2021, with typical shear strength of 4–8 MPa for EVA interlayers. Because EVA interlayer does not match PVB low-temperature impact performance in ECE R43 tests below -20 °C, it is restricted to side and roof glazing rather than primary windshield applications. Compliance markers are ECE R43, ISO 12543-1:2021, ISO 12543-2:2021, and GB 9656 for domestic Chinese automotive glass. The film should be pre-dried at 70–80 °C for 4–6 h when storage relative humidity exceeds 60%, as residual water causes micro-void defects during autoclave cure. Terminal finished product types are laminated side windows, roof glazing, and rear quarter panels for low- to medium-volume automotive programs, not high-volume windshield lines.
Interior partition panels and decorative balustrades containing embedded PET printed film, metal mesh, or textile layers use KENGO ST EVA Film as the bonding interlayer between two tempered or heat-strengthened glass sheets. The film’s melt mass-flow rate is selected in the 10–30 g/10 min range at 190 °C/2.16 kg per ISO 1133-1:2022, so that the softened resin can penetrate fabric interstices without excessive edge squeeze-out. A silane primer is applied to clean glass surfaces at 0.3–0.8 g/m² dry coat weight; the stack is assembled with 0.38 mm or 0.76 mm EVA film on both sides of the decorative insert and passed through a roller press or vacuum-channel pre-laminator at 100–120 °C, 0.5–0.8 MPa for 15–25 min. Final curing takes place in an air-circulating autoclave at 130–140 °C and 0.9–1.2 MPa for 60–120 min. The addition ratio of UV absorber in the EVA layer is 0.2–0.4 phr, and the film contains 0.1–0.2 phr of a non-yellowing antioxidant for PET ink protection under 1000 h QUV-A exposure; batch weathering verification is required because published data for this specific configuration is limited. Haze is measured by ASTM D1003-21 and should remain below 8% for visibly clear zones. Compliance standards include EN 14449 for glass in buildings, ANSI Z97.1 for safety glazing, and EN 12600 pendulum impact classification 1B1 or 2B2 depending on total panel thickness. Terminal finished product types are demountable office partitions, stair balustrades, elevator cab panels, and back-painted decorative wall cladding with laminated glass construction.
KENGO ST EVA Film is applied as a solvent-free hot-melt adhesive film in textile bonding for footwear uppers and leisure goods, where the film is not crosslinked after bonding. The melt flow index is selected between 40–150 g/10 min at 190 °C/2.16 kg per ISO 1133-1:2022 to achieve wetting on polyester, nylon, and PU-coated fabrics without excessive strike-through. Formulation is adjusted with 5–15 phr of a C5 hydrocarbon tackifier and less than 3 phr of paraffin wax as a processing aid; higher tackifier loadings above 8 phr improve initial tack but extend open time and can reduce final bond strength after 24 h conditioning at 23 °C/50% RH. Lamination is carried out on flat-bed or rotary vacuum-forming presses with platen temperature 90–110 °C, applied pressure 0.3–0.6 MPa, and dwell time 20–40 s. Production lines with vertical stroke presses below 100 kN clamping force exhibit non-uniform nip pressure on multi-layer textile stacks, leading to edge lift after 24 h and inconsistent peel values. Compliance is verified against REACH Annex XVII for restricted substances, RoHS 2011/65/EU for electronic manufacturing floors, and ZDHC MRSL 3.1 for leather and textile chemical management. T-peel strength is measured per ISO 11339:2022 with target values of 2.5–5 N/mm for polyester-nylon composites; values below 2.0 N/mm are rejected for performance footwear. The film is not suitable for continuous service above 70 °C and loses peel strength after repeated washing at pH above 10. Terminal finished product types include sport shoe vamp laminates, leather goods reinforcement, and textile-foam composite panels for medical insoles.
Continuous lamination of aluminum composite panels with a low-density polyethylene core uses KENGO ST EVA Film as the bonding layer between 0.3 mm or 0.5 mm aluminum skins and the core. The film is extruded at 80–150 µm thickness and activates between 105 °C and 125 °C; double-belt press line speed is limited to 1.5–3.0 m/min because heat transfer through the aluminum skin must bring the core surface to the film’s activation range before pressure is released. The formulation contains 100 phr EVA base polymer with vinyl acetate content 19–28%, 10–20 phr of C5 or C9 hydrocarbon tackifier, 0.3–0.8 phr silane coupling agent, and 0.1–0.2 phr sulfur-free antioxidant. Aluminum coils are pre-treated with a chromate or titanium-zirconium conversion coating at 6–10 g/m² dry film weight, and coil surface tension must be maintained above 38 mN/m before lamination to prevent starved adhesion at coil edges. Peel strength between aluminum skin and core is measured by ASTM D1781, with typical values from 25 to 60 N/25 mm depending on skin thickness and line speed; production log data indicate that peel strength drops by 10–20% when line speed is raised from 2.0 m/min to 3.0 m/min without increasing belt temperature. Compliance markers for the finished panel are GB/T 17748 and EN 13501-1; with non-fire-retardant polyethylene cores the panel is restricted to interior cladding where classification below B-s2,d0 is not required. Published data for KENGO ST EVA Film in this specific composite configuration is limited, so press temperature profiling and coil adhesion checks are mandatory at the start of each production batch. Terminal finished product types are interior and exterior aluminum composite panels for façade cladding, soffit linings, and signage panels.
In PVC-free medical packaging lines, KENGO ST EVA Film is used as the sealant layer in laminated structures for flexible pouches, IV set overwrap, and diagnostic kit lidding. The film is coextruded or laminated at 25–60 µm thickness, and its ethylene-vinyl acetate content is maintained above 18% for low-temperature seal initiation on rotary tray-sealing equipment with heated die temperature 105–125 °C, dwell time 0.5–1.5 s, and seal pressure 0.4–0.8 MPa. Vinyl acetate content above 28% raises room-temperature blocking tendency, especially when warehouse storage exceeds 30 °C; slip agent addition at 300–800 ppm and antiblock at 500–1200 ppm are used to maintain a coefficient of friction below 0.30 per ASTM D1894-14. Seal strength is tested per ASTM F88/F88M-21, with target values of 2.5–6 N/15 mm for EVA sealant film to PET/PE laminate; sterilization validation requires that seal strength after ethylene oxide or gamma radiation does not fall below 80% of the original value. Regulatory compliance is maintained under ISO 11607-1:2019 and ISO 11607-2:2019 for packaging of terminally sterilized medical devices, EN 868-5 for steam sterilizer pouches, and FDA 21 CFR 177.1350 for ethylene-vinyl acetate copolymers in food-contact and medical applications. The film is not suitable for autoclave conditions above 121 °C unless the sealant structure is upgraded with a higher-heat-resistance copolymer blend. Terminal finished product types are flexible medical pouches, IV set overwrap, diagnostic kit lidding, and fluid drainage pouch laminations.
Competitive KENGO ST EVA Film prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8615380400285 or mail to sales2@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8615380400285
Email: sales2@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
KENGO ST EVA Film is a peroxide-curable ethylene-vinyl acetate encapsulant supplied as a continuous cast film for photovoltaic module lamination. The model suffix ST identifies the fast-cure grade within the KENGO EVA Film portfolio and is specified for both glass/backsheet and glass/glass crystalline silicon architectures. Commercial supply formats include nominal thicknesses of 0.45 mm, 0.50 mm, and 0.65 mm, with roll widths up to 2200 mm, a thickness tolerance of ±10%, and a width tolerance of ±2 mm. The uncured film is single-side embossed with an average surface roughness of Ra 3–8 µm measured by ISO 4287:1997, which provides interlaminar air evacuation during vacuum lamination. The resin composition is formulated to a vinyl acetate content of 28–33 wt% with a peroxide crosslinking package; after lamination, the cured encapsulant develops a gel content above 80% when measured by ASTM D2765-16. Melt flow rate of the uncured film is typically 20–35 g/10 min at 190 °C and 2.16 kg per ISO 1133-1:2022. The film is positioned between the glass, cell string, and backsheet, where silane coupling chemistry provides adhesion to glass and hot-melt bonding provides adhesion to the backsheet. The ST formulation is selected when a laminator must operate with shorter dwell times than a standard-cure EVA grade without switching to a fundamentally different encapsulant chemistry.
On a three-chamber vacuum laminator with a usable platen area of 2.2 m × 1.1 m and silicone membrane pressure maintained at 100–110 kPa, the fast-cure formulation permits a total cycle of 10–12 min for a 0.45 mm film in a glass/backsheet stack when the platen setpoint is 145–155 °C. The same cycle extends to 12–15 min for a 0.65 mm film because the thicker encapsulant acts as a thermal resistor between the glass and cell plane. Crosslinking accelerates with platen temperature; below 140 °C, gel content determined by ASTM D2765-16 is frequently below 70%, which is insufficient for creep resistance and damp-heat adhesion retention in IEC 61215-2:2021 qualification. Above 160 °C, the peroxide decomposes too rapidly, producing volatile decomposition products faster than the vacuum step can remove them, with bubble formation at cell ribbon crossings and edge regions. The practical processing window is therefore ±5 °C around the recommended platen setpoint, and platen uniformity should be verified with a multi-point contact thermocouple array to maintain a temperature spread below ±2 °C. Degassing time before membrane pressurization should be no less than 5 min; insufficient degassing produces void clustering at the busbar interface.
The vulcanization kinetics of the ST grade are shifted to reduce time-at-temperature above the peroxide decomposition onset. During cure at 150 °C, oscillatory rheometry at 1 Hz shows an initial storage modulus below 1×10^5 Pa for the molten film; after 6–8 min, the modulus crosses 1×10^6 Pa and reaches a plateau when gel content reaches 80%. The gel point, defined by the crossover of storage and loss modulus, occurs at approximately 50–60% of the total cure time under the recommended platen temperature. This viscoelastic transition is process-relevant because cell string movement is prevented only after gelation; if membrane pressure is applied too early, cell shifting and ribbon deformation occur. Peak cure exotherm by differential scanning calorimetry at 10 °C/min is 15–25 W/g, measured under ASTM E2160-04. Published data for a specific laminator model and backsheet combination is limited; final cycle time must be confirmed by gel content and peel testing on the target line.
In cast film production, the compounded EVA resin is plastified in a single-screw extruder with a 75–90 mm screw diameter and L/D 30:1, using barrel and adaptor zones held between 80 °C and 110 °C and a slot die maintained at 90–120 °C. Compounding upstream of the film line may use a co-rotating twin-screw extruder with L/D 44:1 and a screw speed of 200–400 rpm to disperse the peroxide masterbatch and stabilizers without local hot spots that would trigger premature decomposition. The melt exits the die into a chilled roll stack at 15–25 °C; rewind tension is maintained at 10–25 N/m. Winding tension above 30 N/m has been observed to create roll blocking and surface imprinting that later appear as laminate voids under ASTM D1003-21 transmitted-light inspection. Cross-web thickness variation on a 2200 mm web should remain below ±5%; larger variation produces edge squeeze-out during lamination. Slitting in a cleanroom converting step uses rotary blade gaps of 0.05–0.10 mm; edge burrs produced at larger gaps are a recurring source of delamination initiation because the jagged film edge prevents complete vacuum withdrawal at the laminate perimeter.
For glass/glass modules, the same ST film is used in either a two-step vacuum bag process or a single-chamber laminator with edge clamps. The absence of a flexible backsheet changes the pressure distribution; membrane pressure must be reduced to 80–95 kPa for the first 3–4 min until the edges are sealed, then raised to 100–110 kPa for the curing plateau. If full pressure is applied too early, the encapsulant can be squeezed out at the perimeter and cell strings can shift by more than 1 mm. Edge-squeeze-out weights above 3 g/m are associated with visible edge voids and reduced insulation resistance in the module frame after IEC 61730-1:2021 wet insulation testing.
The cured encapsulant is tested as a laminate rather than as a free film. Luminous transmittance through a glass/encapsulant/glass stack is typically above 91% for a 0.45 mm film and above 90% for a 0.65 mm film when measured with an integrating sphere according to ASTM D1003-21; haze after lamination is below 5%. Ultraviolet screening is obtained from the glass and from stabilizer loading in the film; total hemispherical transmittance of the laminate stack per ASTM E903-20 is typically above 89%. The UV cut-on wavelength for 50% transmittance is 360–380 nm. Yellowing index measured by ASTM E313-20 remains below 2.0 after 1000 h damp heat at 85 °C/85 % RH under IEC 61215-2:2021. Peel adhesion to glass, measured by ASTM D903-98(2017) with a 10 mm strip, remains above 60 N/cm after the same damp-heat exposure. Volume resistivity at 500 V DC is above 1×10^14 Ω·cm per IEC 62788-1-2:2020, sufficient for electrical isolation in crystalline silicon modules when combined with the backsheet. The following comparison is based on typical values for commercially available fast-cure EVA, standard-cure EVA, and polyolefin encapsulant films; final qualification values are construction-dependent.
| Property | Test method | KENGO ST EVA Film | Standard-cure EVA | POE encapsulant |
|---|---|---|---|---|
| Cure type | — | Peroxide crosslinked | Peroxide crosslinked | Peroxide crosslinked or thermoplastic |
| Laminator dwell at 150 °C | Internal lamination trial | 10–12 min | 16–20 min | 10–14 min |
| Gel content after cure | ASTM D2765-16 | 80–90% | 75–90% | 60–85% |
| Luminous transmittance | ASTM D1003-21 | >91% | >90% | >91% |
| Peel adhesion to glass | ASTM D903-98(2017) | >60 N/cm | >50 N/cm | >70 N/cm |
| Volume resistivity at 500 V DC | IEC 62788-1-2:2020 | >1×10^14 Ω·cm | >1×10^14 Ω·cm | >1×10^15 Ω·cm |
Because the polymer backbone is vinyl acetate, hydrolytic degradation under damp heat releases acetic acid. The rate is reduced in the ST formulation by the lower time-at-temperature during lamination and by the stabilizer package, but the mechanism is not eliminated. In accelerated testing at 85 °C/85 % RH, front-side glass adhesion remains above 60 N/cm for 1000 h, but modules with unsealed edges can show onset of solder-ribbon discoloration after 1500–2000 h depending on backsheet water vapor transmission rate. The migration kinetics of acetic acid in the cured polymer matrix is slow at module operating temperature but accelerates above the glass transition of the cured film; edge-region acetate concentration after 1000 h damp heat is typically below 500 µg/g in properly cured laminates, although published data for the KENGO ST film in this specific configuration is limited. For thin-film devices with transparent conductive oxides, acetic acid release can sensitize the cell edge; in these configurations, an edge seal or non-acetic encapsulant should be evaluated. This constraint is specific to EVA chemistry and is the principal reason a polyolefin encapsulant may be substituted when moisture-sensitive interconnects or transparent conductive oxides dominate the bill of materials.
Before a roll is opened in a cleanroom, the receiving area should verify that the desiccant packaging is intact and that the roll core has not been exposed to condensation. Rolls should be stored in sealed desiccant packaging at 0–25 °C and relative humidity below 50%; storage life from date of manufacture is typically 12 months under these conditions. If the packaging is opened at an ambient relative humidity above 60%, the film absorbs moisture rapidly, and moisture uptake above 0.1 wt% by Karl Fischer titration produces bubbles at the glass interface during lamination. Pre-drying at 60–70 °C for 4–8 h is required before use after high-humidity exposure. The film should not be stored near organic solvents, silicone release liners, or amine-containing cleaning agents; amine species can neutralize the silane adhesion promoter and reduce dry peel strength below 40 N/cm even when cure is otherwise complete. Rolls should be re-wrapped with moisture-barrier foil after partial consumption and returned to 15–25 °C storage within 30 min of exposure to the cleanroom atmosphere.
| Requirement | Designation | Method / status |
|---|---|---|
| Restriction of Hazardous Substances | RoHS Directive 2011/65/EU | Declared compliant for Pb, Cd, Hg, Cr(VI), PBB, PBDE |
| EU chemical registration | REACH Regulation (EC) No 1907/2006 | SVHC declaration below 0.1 wt% per article |
| Photovoltaic module qualification | IEC 61215-2:2021 | Encapsulant qualified in a specific laminate stack |
| Safety qualification | IEC 61730-1:2021 | Insulation coordination supported by volume resistivity per IEC 62788-1-2:2020 |
| Flammability classification | UL 94 / IEC 61730-2:2021 | Module-level fire test per target market |
Selection among KENGO ST EVA Film, a standard-cure EVA, and a polyolefin encapsulant is governed by the interaction of laminator throughput, backsheet thermal stability, edge-seal design, and ion migration risk. The ST grade reduces the dwell below the peroxide decomposition threshold by roughly 30–40% compared with standard-cure EVA; this difference is significant on a three-chamber laminator because the backsheet is not held at 150 °C for the same duration. However, the cured film remains an EVA chemistry, with a water vapor transmission rate higher than a typical polyolefin encapsulant. In glass/backsheet modules with fluoropolymer or polyester backsheets and standard ribbon interconnects, the ST grade is used to increase line speed without changing to a higher-cost encapsulant. In glass/glass modules with moisture-sensitive cell metallization or field exposure in coastal climates, the edge seal and perimeter drainage design become critical; if the edge seal is incomplete, moisture ingress can produce acetic acid accumulation and ion migration along the cell string within 1000–1500 h of damp heat. Polyolefin encapsulants may provide lower water vapor transmission and higher volume resistivity, but their adhesion to glass and their cost profile differ. The KENGO ST EVA Film is therefore positioned for high-throughput crystalline silicon lines where proven silane adhesion, short cure time, and established module qualification history are weighted more heavily than the moisture-barrier advantages of polyolefin alternatives. Before production adoption, the complete module stack should be qualified to IEC 61215-2:2021, IEC 61730-1:2021, and the relevant fire test standard for the target market because encapsulant performance is not separable from glass, backsheet, and edge-seal interactions.
For laminators operated at sites above 1800 m, the vacuum system must compensate for lower ambient pressure. If external barometric pressure falls below 80 kPa, the pump should maintain an absolute chamber pressure below 5 kPa during the degassing step to preserve the same differential pressure across the membrane. Film embossing depth on the ST grade is optimized for standard sea-level vacuum levels; at high-altitude sites, an increase in emboss depth or a longer degassing time may be required to prevent air entrapment at the cell string edges.